{"created":"2023-06-19T12:44:35.166104+00:00","id":4080,"links":{},"metadata":{"_buckets":{"deposit":"35907a01-af49-40d1-9fe8-ef7928924741"},"_deposit":{"created_by":3,"id":"4080","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"4080"},"status":"published"},"_oai":{"id":"oai:tokyo-metro-u.repo.nii.ac.jp:00004080","sets":["1381:657:658:659:668"]},"author_link":["12931","12933","12926","12932","12940","12942","12924","12930","12929","12927","12925","12935","12934","12941","12936","12943","12937","12928","12923","12939","12938"],"item_3_alternative_title_19":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A Study of Characteristics of X-ray Generators and Exposure Dose"}]},"item_3_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"48","bibliographicPageStart":"39","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"東京都立医療技術短期大学紀要 = Bulletin of Tokyo Metropolitan College of Allied Medical Sciences"}]}]},"item_3_creator_2":{"attribute_name":"著者(ヨミ)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"アベ, シンジ"}],"nameIdentifiers":[{"nameIdentifier":"12930","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ネギシ, トオル"}],"nameIdentifiers":[{"nameIdentifier":"12931","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"オグラ, イズミ"}],"nameIdentifiers":[{"nameIdentifier":"12932","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"カトウ, ヨウ"}],"nameIdentifiers":[{"nameIdentifier":"12933","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"アオヤギ, タイジ"}],"nameIdentifiers":[{"nameIdentifier":"12934","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ナカヤ, ギイチロウ"}],"nameIdentifiers":[{"nameIdentifier":"12935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"クマガイ, ヨウコ"}],"nameIdentifiers":[{"nameIdentifier":"12936","nameIdentifierScheme":"WEKO"}]}]},"item_3_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Abe, Shinji"}],"nameIdentifiers":[{"nameIdentifier":"12937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Negishi, Toru"}],"nameIdentifiers":[{"nameIdentifier":"12938","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ogura, Izumi"}],"nameIdentifiers":[{"nameIdentifier":"12939","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katoh, You"}],"nameIdentifiers":[{"nameIdentifier":"12940","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Aoyagi, Taiji"}],"nameIdentifiers":[{"nameIdentifier":"12941","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakaya, Giichiro"}],"nameIdentifiers":[{"nameIdentifier":"12942","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kumagai, Yoko"}],"nameIdentifiers":[{"nameIdentifier":"12943","nameIdentifierScheme":"WEKO"}]}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"現在,診断用X線装置は単相装置,三相装置,コンデンサ式装置,インバータ式装置などが普及している。今回,これらの装置の高電圧測定,線量測定,波形解析を行い,百分率平均誤差,再現性,X線出力,写真効果,被曝線量などについて検討した。インバータ式装置の特性は優れているが,単相装置とコンデンサ式装置はX線出力と被曝線量の点で問題がある。X線装置の高電圧波形は矩形波に近いものが望ましく,X線撮影にはこれらの装置の特性を十分認識する必要がある。","subitem_description_type":"Abstract"},{"subitem_description":"Up to now in Japan, shingle phase, three phase, capacitor discharge type and inverter type X-ray generators have mainly been used in the diagnostic X-ray generator.\nIn this study, the authors investigated the characteristics of these generators. Their percentage of ripple, percent average error (PAE), reproducibilities, X-ray output, photographic effect and exposure does were examined and a waveform analysis was performed.\nAs a result, single phase and capacitor discharge type X-ray generators presented some \nproblems as to X-ray output and exposure dose. The characteristics of the inverter type X-ray generator were excellent. It is desirable that high voltage waveforms of X-ray generators should be rectangular waveforms. We have to recognize the characteristics of these generators in radiography.","subitem_description_type":"Abstract"}]},"item_3_publisher_33":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"東京都立医療技術短期大学紀要委員会"}]},"item_3_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN1010184X","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916040X","subitem_source_identifier_type":"ISSN"}]},"item_3_version_type_16":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"安部, 真治"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"根岸, 徹"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小倉, 泉"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"加藤, 洋"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"青柳, 泰司"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中谷, 儀一郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"熊谷, 曜子"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-08-04"}],"displaytype":"detail","filename":"10277-001.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"10277-001.pdf","url":"https://tokyo-metro-u.repo.nii.ac.jp/record/4080/files/10277-001.pdf"},"version_id":"4552d9e5-a2af-4416-a0e6-8e8bae6db0de"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"X線装置","subitem_subject_scheme":"Other"},{"subitem_subject":"特性解析","subitem_subject_scheme":"Other"},{"subitem_subject":"X線出力","subitem_subject_scheme":"Other"},{"subitem_subject":"写真効果","subitem_subject_scheme":"Other"},{"subitem_subject":"被曝線量","subitem_subject_scheme":"Other"},{"subitem_subject":"X-ray generator","subitem_subject_scheme":"Other"},{"subitem_subject":"Analysis of Characteristics","subitem_subject_scheme":"Other"},{"subitem_subject":"X-ray output","subitem_subject_scheme":"Other"},{"subitem_subject":"Photographic effect","subitem_subject_scheme":"Other"},{"subitem_subject":"Exposure dose","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"X線装置の諸特性と被曝線量の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"X線装置の諸特性と被曝線量の検討"}]},"item_type_id":"3","owner":"3","path":["668"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-11-09"},"publish_date":"2011-11-09","publish_status":"0","recid":"4080","relation_version_is_last":true,"title":["X線装置の諸特性と被曝線量の検討"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T18:02:26.919688+00:00"}