{"created":"2023-12-04T07:37:19.617653+00:00","id":2000140,"links":{},"metadata":{"_buckets":{"deposit":"f41f7b59-087d-403f-a12b-5fa04b79c01c"},"_deposit":{"created_by":14,"id":"2000140","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"2000140"},"status":"published"},"_oai":{"id":"oai:tokyo-metro-u.repo.nii.ac.jp:02000140","sets":["656:675:676"]},"author_link":[],"control_number":"2000140","item_30002_alternative_title1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"脳卒中片麻痺患者におけるHONDA 歩行アシストの即時効果に対する足部・足関節機能","subitem_alternative_title_language":"ja"}]},"item_30002_bibliographic_information29":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"409","bibliographicPageStart":"405","bibliographicVolumeNumber":"32","bibliographic_titles":[{"bibliographic_title":"Journal of physical therapy science","bibliographic_titleLang":"en"}]}]},"item_30002_creator2":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Satoh, Yoshinao","creatorNameLang":"en"},{"creatorName":"佐藤,義尚","creatorNameLang":"ja"},{"creatorName":"サトウ, ヨシナオ","creatorNameLang":"ja-Kana"}]},{"creatorNames":[{"creatorName":"Yamada, Takumi","creatorNameLang":"en"},{"creatorName":"山田, 拓実","creatorNameLang":"ja"},{"creatorName":"ヤマダ, タクミ","creatorNameLang":"ja-Kana"}]},{"creatorNames":[{"creatorName":"Arai, Yasuhisa","creatorNameLang":"en"},{"creatorName":"新井, 康久","creatorNameLang":"ja"},{"creatorName":"アライ, ヤスヒサ","creatorNameLang":"ja-Kana"}]},{"creatorNames":[{"creatorName":"Shimamura, Ryota","creatorNameLang":"en"},{"creatorName":"島村, 亮太","creatorNameLang":"ja"},{"creatorName":"シマムラ, リョウタ","creatorNameLang":"ja-Kana"}]},{"creatorNames":[{"creatorName":"Hirosawa, Masaki","creatorNameLang":"en"},{"creatorName":"廣澤.全紀","creatorNameLang":"ja"},{"creatorName":"ヒロサワ.マサキ","creatorNameLang":"ja-Kana"}]},{"creatorNames":[{"creatorName":"Yamakawa, Ryota","creatorNameLang":"en"},{"creatorName":"山川, 諒太","creatorNameLang":"ja"},{"creatorName":"ヤマカワ, リョウタ","creatorNameLang":"ja-Kana"}]},{"creatorNames":[{"creatorName":"Takagi, Shota","creatorNameLang":"en"},{"creatorName":"高城, 翔太","creatorNameLang":"ja"},{"creatorName":"タカギ, ショウタ","creatorNameLang":"ja-Kana"}]}]},"item_30002_description9":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"[Purpose] We evaluated the reliability of the measurement function of the Honda Walking Assist Device and investigated the effect of the device on walking improvements, and foot and ankle function, in hemiplegic stroke patients. [Participants and Methods] We recruited 16 hemiplegic stroke patients who performed 10-meter walk tests, twice without assistance and once with device assistance. Based on the rate of change of velocity, we divided the participants into two groups and compared the walking parameters, the toe grip strength, the cross tests, and the maximum step width. Two examiners assessed the 10-meter walk test results, and the authors calculated the intraclass correlation coefficients for walking speed, stride length, cadence, flexion, extension, and scissor angles. [Results] The intraclass correlation coefficients were greater than 0.70 for all the walking parameters we measured. The device increased hip joint movement but did not alter the maximum walking speed of the stroke patients. The patients in the group with a greater change in velocity displayed lower toe grip strength and decreased maximum step width and used orthoses more commonly. [Conclusion] The walking measurement function of the device was reliable. The immediate effect of the device in stroke patients may be influenced by the level of paralysis and the presence of an orthosis.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"東京都立大学学位論文甲第1239号 副論文","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"学位申請時氏名:森山 義尚","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_30002_file35":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-11-28"}],"displaytype":"detail","filename":"11120-001.pdf","format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://tokyo-metro-u.repo.nii.ac.jp/record/2000140/files/11120-001.pdf"},"version_id":"270151fb-9ece-4d97-ac50-1f8bc8e34158"}]},"item_30002_identifier16":{"attribute_name":"識別子","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"https://doi.org/10.1589/jpts.32.405"}]},"item_30002_language12":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_30002_publisher10":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Society of Physical Therapy Science","subitem_publisher_language":"en"},{"subitem_publisher":"理学療法科学学会","subitem_publisher_language":"ja"}]},"item_30002_relation18":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"32581434","subitem_relation_type_select":"PMID"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"2021088513","subitem_relation_type_select":"ICHUSHI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"130007851472","subitem_relation_type_select":"NAID"}},{"subitem_relation_name":[{"subitem_relation_name_language":"en","subitem_relation_name_text":"Movement patterns of the functional reach test do not reflect physical function in healthy young and older participants"},{"subitem_relation_name_language":"ja","subitem_relation_name_text":"健常若年者と高齢者におけるファンクショナルリーチテストの運動パターンは身体機能を反映しない"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://hdl.handle.net/10748/0002000100","subitem_relation_type_select":"HDL"}},{"subitem_relation_name":[{"subitem_relation_name_language":"ja","subitem_relation_name_text":"収録先の学位論文「Movement patterns of the functional reach test do not reflect physical function in healthy young and older participants」(東京都立大学, 2022-09-30, 博士(理学療法学), 甲第1239号)(http://hdl.handle.net/10748/0002000100)"}]}]},"item_30002_resource_type13":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_30002_source_identifier22":{"attribute_name":"収録物識別子","attribute_value_mlt":[{"subitem_source_identifier":"09155287","subitem_source_identifier_type":"PISSN"},{"subitem_source_identifier":"AA10798949","subitem_source_identifier_type":"NCID"}]},"item_30002_subject8":{"attribute_name":"主題","attribute_value_mlt":[{"subitem_subject":"Honda Walking Assist Device","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Hemiplegic stroke","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Foot and ankle function","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_30002_title0":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The immediate effect of the Honda Walking Assist Device on foot and ankle function in hemiplegic stroke patients","subitem_title_language":"en"}]},"item_30002_version_type15":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_title":"The immediate effect of the Honda Walking Assist Device on foot and ankle function in hemiplegic stroke patients","item_type_id":"30002","owner":"14","path":["676"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-11-28"},"publish_date":"2023-11-28","publish_status":"0","recid":"2000140","relation_version_is_last":true,"title":["The immediate effect of the Honda Walking Assist Device on foot and ankle function in hemiplegic stroke patients"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2024-04-03T03:39:27.849005+00:00"}