WEKO3
アイテム
{"_buckets": {"deposit": "feb2744a-a9ae-46bf-b3a9-695fbce1e8e8"}, "_deposit": {"created_by": 3, "id": "4250", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "4250"}, "status": "published"}, "_oai": {"id": "oai:tokyo-metro-u.repo.nii.ac.jp:00004250", "sets": ["684"]}, "author_link": ["14089", "14102", "14101", "14097", "14103", "14091", "14094", "14108", "14095", "14105", "14106", "14093", "14092", "14088", "14099", "14107", "14100", "14096", "14098", "14104", "14090"], "item_6_alternative_title_19": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Quantitative Assessment of Wall Motion in Gated SPECT Using the Centerline Method"}]}, "item_6_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "821", "bibliographicPageStart": "814", "bibliographicVolumeNumber": "64", "bibliographic_titles": [{"bibliographic_title": "日本放射線技術学会雑誌"}]}]}, "item_6_creator_2": {"attribute_name": "著者(ヨミ)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "イマエ, トシカズ"}], "nameIdentifiers": [{"nameIdentifier": "14095", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "フジイ, ケイタ"}], "nameIdentifiers": [{"nameIdentifier": "14096", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "タカノ, マサアキ"}], "nameIdentifiers": [{"nameIdentifier": "14097", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ヤマザキ, ジュンイチ"}], "nameIdentifiers": [{"nameIdentifier": "14098", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "イイダ, キョウヒト"}], "nameIdentifiers": [{"nameIdentifier": "14099", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ミマ, カズオ"}], "nameIdentifiers": [{"nameIdentifier": "14100", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "シノハラ, ヒロユキ"}], "nameIdentifiers": [{"nameIdentifier": "14101", "nameIdentifierScheme": "WEKO"}]}]}, "item_6_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Imae, Toshikazu"}], "nameIdentifiers": [{"nameIdentifier": "14102", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujii, Keita"}], "nameIdentifiers": [{"nameIdentifier": "14103", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takano, Masaaki"}], "nameIdentifiers": [{"nameIdentifier": "14104", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamazaki, Junichi"}], "nameIdentifiers": [{"nameIdentifier": "14105", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iida, Kyohito"}], "nameIdentifiers": [{"nameIdentifier": "14106", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mima, Kazuo"}], "nameIdentifiers": [{"nameIdentifier": "14107", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinohara, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "14108", "nameIdentifierScheme": "WEKO"}]}]}, "item_6_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Evaluation of myocardial wall motion is an important assessment of heart function. Specific analysis programs in nuclear medicine, such as QGS (quantitative gated SPECT) analysis and p-FAST (perfusion-function assessment for myocardial SPECT), have been used to assess wall motion, but they have not evaluated it through a comparison of normal data. The centerline method, using left ventriculograms (LVG), evaluates regional wall motion quantitatively through a comparison of normal data and patient data, and abnormality of wall motion is expressed in units of standard deviation (SD) s from the mean motion in a reference population. However, angiography is an invasive inspection, wall motion analysis is usually in one direction, and the conventional centerline method is not a three-dimensional analysis. The purpose of this study was to apply the centerline method to nuclear medicine and examine the wall motion of subjects through a comparison of normal wall motion non-invasively and in a three-dimensional way. We arranged the analysis program using C language and inspected it using a dynamic cardiac phantom and computed tomography (CT) scanner. We made a polar map that indicated the mean and SD of normal wall motion. Our proposed method was able to assess the wall motion of subjects quantitatively through a comparison of normal wall motion in nuclear medicine.", "subitem_description_type": "Abstract"}]}, "item_6_publisher_33": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本放射線技術学会"}]}, "item_6_rights_13": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "日本放射線技術学会"}]}, "item_6_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00197784", "subitem_source_identifier_type": "NCID"}]}, "item_6_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03694305", "subitem_source_identifier_type": "ISSN"}]}, "item_6_version_type_16": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "今江, 禄一"}], "nameIdentifiers": [{"nameIdentifier": "14088", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤井, 佳太"}], "nameIdentifiers": [{"nameIdentifier": "14089", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高野, 政明"}], "nameIdentifiers": [{"nameIdentifier": "14090", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山崎, 純一"}], "nameIdentifiers": [{"nameIdentifier": "14091", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯田, 恭人"}], "nameIdentifiers": [{"nameIdentifier": "14092", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "美馬, 和男"}], "nameIdentifiers": [{"nameIdentifier": "14093", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "篠原, 広行"}], "nameIdentifiers": [{"nameIdentifier": "14094", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-08-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "10245-001.pdf", "filesize": [{"value": "1.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1500000.0, "url": {"label": "10245-001.pdf", "url": "https://tokyo-metro-u.repo.nii.ac.jp/record/4250/files/10245-001.pdf"}, "version_id": "b2c015be-dec1-48e8-8b3c-c02ac820bf7f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "gated single photon emission computed tomography (gated SPECT)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "centerline method", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wall motion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "quantitative assessment", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "心電図同期心筋血流SPECTによるcenterline法を用いた壁運動定量評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "心電図同期心筋血流SPECTによるcenterline法を用いた壁運動定量評価"}]}, "item_type_id": "6", "owner": "3", "path": ["684"], "permalink_uri": "http://hdl.handle.net/10748/4174", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-09-28"}, "publish_date": "2011-09-28", "publish_status": "0", "recid": "4250", "relation": {}, "relation_version_is_last": true, "title": ["心電図同期心筋血流SPECTによるcenterline法を用いた壁運動定量評価"], "weko_shared_id": 3}
心電図同期心筋血流SPECTによるcenterline法を用いた壁運動定量評価
http://hdl.handle.net/10748/4174
http://hdl.handle.net/10748/41745877ab5d-c8ec-4c21-9931-a2af8584ebe0
名前 / ファイル | ライセンス | アクション |
---|---|---|
10245-001.pdf (1.5 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-09-28 | |||||
タイトル | ||||||
タイトル | 心電図同期心筋血流SPECTによるcenterline法を用いた壁運動定量評価 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | gated single photon emission computed tomography (gated SPECT) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | centerline method | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | wall motion | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | quantitative assessment | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
今江, 禄一
× 今江, 禄一× 藤井, 佳太× 高野, 政明× 山崎, 純一× 飯田, 恭人× 美馬, 和男× 篠原, 広行 |
|||||
著者(ヨミ) |
イマエ, トシカズ
× イマエ, トシカズ× フジイ, ケイタ× タカノ, マサアキ× ヤマザキ, ジュンイチ× イイダ, キョウヒト× ミマ, カズオ× シノハラ, ヒロユキ |
|||||
著者別名 |
Imae, Toshikazu
× Imae, Toshikazu× Fujii, Keita× Takano, Masaaki× Yamazaki, Junichi× Iida, Kyohito× Mima, Kazuo× Shinohara, Hiroyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Evaluation of myocardial wall motion is an important assessment of heart function. Specific analysis programs in nuclear medicine, such as QGS (quantitative gated SPECT) analysis and p-FAST (perfusion-function assessment for myocardial SPECT), have been used to assess wall motion, but they have not evaluated it through a comparison of normal data. The centerline method, using left ventriculograms (LVG), evaluates regional wall motion quantitatively through a comparison of normal data and patient data, and abnormality of wall motion is expressed in units of standard deviation (SD) s from the mean motion in a reference population. However, angiography is an invasive inspection, wall motion analysis is usually in one direction, and the conventional centerline method is not a three-dimensional analysis. The purpose of this study was to apply the centerline method to nuclear medicine and examine the wall motion of subjects through a comparison of normal wall motion non-invasively and in a three-dimensional way. We arranged the analysis program using C language and inspected it using a dynamic cardiac phantom and computed tomography (CT) scanner. We made a polar map that indicated the mean and SD of normal wall motion. Our proposed method was able to assess the wall motion of subjects quantitatively through a comparison of normal wall motion in nuclear medicine. | |||||
書誌情報 |
日本放射線技術学会雑誌 巻 64, 号 7, p. 814-821, 発行日 2008 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 03694305 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00197784 | |||||
権利 | ||||||
権利情報 | 日本放射線技術学会 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
その他のタイトル | ||||||
その他のタイトル | Quantitative Assessment of Wall Motion in Gated SPECT Using the Centerline Method | |||||
出版者 | ||||||
出版者 | 日本放射線技術学会 |